History About ISO
Menyambut Anniversary 100 Tahun VESSEL pada 2016 mendatang, dapatkan berbagai produk baru kami yang akan di Launching pada 2016


The Shop

LoadingUpdating...
Ion Parts Cleaner

 

VESSEL IPC-A3 : Ion Parts Cleaner

* An openable clear window is provided on the front of the hood to prevent sdust from scattering and to ensure a clear view.
* The adhesive gel sheet can be easily washed and replaced. The adhesive gel sheet plate is attached with magnets, and can be easily removed.
* A paper pack filter or dust hose for collecting dust can be attached to the back of the hood.
* Two air nozzle type ionizers are set on the top of the hood to blow air downward. The ionized air discharged from the ionizers simultaneously removes static electricity and dust from the workpiece.
* When a workpiece is inserted into the hood by hand, the sensor activates and automatically starts the air blow.
* The static electricity remover is equipped with an error monitor function. Error states can be checked with lamp indications.
* RoHS compatible product, CE complaint product (EMC Directive)
VESSEL IPC-A3 : Ion Parts CleanerDetail Produk

IPC-A3 Ion Parts Cleaner



* Input voltage : DC24V±5%
* Power consumption : 22 W
* Current consumption : 900mA
* Air Flow : 1.13 m3/min (Built-in fan)
* Static Pressure : 460Pa (Built-in fan)
* Ionizer : Super Slim Nozzle-Type N-1 x 2pcs
* Applied fluid : 0.1Mpa to 0.7MPa (use clesn air)
* Air consumption : 220L/min (0.3MPa)
* Air supply hose diameter : Ø8mm ×Ø5mm
* Noise : 70.0 dBA (0.3MPa)
* Operating temperature and humidity : 5°C to 40°C and 35 to 65%RH (non-condensing)
* Materials : Booth : Steel, Hard PVC plates / Plates : Stainless steel / Adhesive gel : Polyurethane

*Accesories : Power supply transformer, Duct flange (for Ø75mm), Paper pack filter (6pc)

Download cataog
Download






VESSEL IPC-A4 : Ion Parts Cleaner

* Compact sized and ideal for dust elimination of small work material.
* Transparent booth with magnifying lens for optimum workability.
* Ionizing air blow can be switched between Pulse mode and Continuous mode.
* With a built-in sensor, which senses parts put into the booth and automatically starts ionizing blow. Auto switch-off time is adjustable.
* Dust are collected on the adhesive surface of the polyurethane gel sheets, which are washable.
* With no built-in dust collector, its power consumption is less than 4% (17W) of a conventional small-sized dust collector.
* Ideal for removing dust and static charge from circuit board and semiconductor devices, and for cleaning part trays and removing dust from lens and acrylic products, neutralizing static charge and eliminating dust before UV protection treatment, vapor deposition, packaging and printing process, etc.
VESSEL IPC-A4 : Ion Parts CleanerDetail Produk

VESSEL IPC-A4 : Ion Parts Cleaner



* Input voltage : DC24V±5%
* Power consumption : 17 W
* Current consumption : 700mA
* Applied fluid : Clean air (0.1~0.3MPa)
* Air consumption : 187L/min (0.3MPa, Continuous mode)
* Modes for Ionizing blow : Continuous mode
- High-frequency pulse mode (Cycle length : 100msec, Pulse width : 40msec)
- Low-frequency pulse mode (Cycle length : 250msec, Pulse width : 100msec)
* OFF-timer setting : 1 / 2 / 5 / 10 / 30 seconds (selected by DIP switch)
* Noise : 86.5dB (A) (0.3MPa, Continuous mode, 1m distance in the front position)
* Ozone generation : Less than 0.05ppm (measured 50mm from device)
* Operating temperature / humidity : 5 - 40°C / 35 – 65%RH (non-condensing)

Accesories:
* Power supply transformer (Input AC100 to 240V Output DC24V)
* Mounting bracket for N-2, Electrode Needle Replacement Screwdriver (separately sold)

Download cataog
Download






VESSEL IPC20-E : Ion Parts Cleaner

* Compact, integrated design is ideal for use in a cell production setting or confined space.
* A photoelectric sensor is used to emit a stream of dust-eliminating air. Can be used one-handed.
* Ships with one compact, powerful SDJ-08 Ionizing Mini-Fan.
* The dust collector motor incorporates an overload prevention function.
* Includes control circuitry to activate the ionizer’s power supply after the air inside the hood has been exhausted. To prevent dust explosions, power is supplied to the ionizer 5 seconds after the dust collector starts operating.
* The dust collector uses a cylindrical cartridge filter for easy maintenance.
VESSEL IPC20-E : Ion Parts CleanerDetail Produk

IPC20-E?Ion Parts Cleaner (Ionizer + Vacuum)



* Dust collection method : Cylindrical cartridge filter
* Input power supply : Single-phase AC230V (50/60 Hz)
* Power consumption : 70 W (50 Hz) / 75 W (60 Hz)
* Current consumption : 0.42 A (50 Hz) / 0.4 A (60 Hz)
* Dust collection airflow : 1.6 m3/min (50 Hz) / 2.0 m3/min (60 Hz)
* Static pressure : 0.35 kPa (50 Hz) / 0.50 kPa (60 Hz)
* Table surface controlled air speed : 0.8 m/sec (50 Hz) / 1.0 m/sec (60 Hz)
* Dust collection volume : 0.5 L
* Dust collector output : 50 W
* Max. airflow : 0.4 MPa to 0.7 MPa (use clean air)
* Air supply hose diameter : 6 mm × 4 mm
* Airflow : 355 L/min (at 0.7 MPa)
* Operating temperature and humidity : 0°C to 40°C, 20% to 80% RH (non-condensing, non-freezing)
* Noise : 56 dB (A) (50 Hz) / 58 dB (A) (60 Hz)
* Accessories : Plastic adjusting screwdriver for sensor, hazardous use prohibited display sheet






VESSEL IPC40-E : Ion Parts Cleaner

* Separate type features a dust collector and standalone hood to make effective use of limited space.
* An infrared sensor is used to emit a stream of dust-eliminating air. Flexible nozzles can be used to fine-tune the direction of airflow.
* Ships with one compact, powerful Ionizing Fan.
* The dust collector motor incorporates an overload prevention function.
* Includes control circuitry to activate the static electricity eraser’s power supply after the gases inside the hood have been exhausted. To prevent dust explosions, power is supplied to the ionizer 7 seconds after the dust collector starts operating.
* The dust collector uses a cylindrical cartridge filter for easy maintenance.
VESSEL IPC40-E : Ion Parts CleanerDetail Produk

IPC40-E Ion Parts Cleaner (Ionizer + Vacuum)



* Dust collection method : Cylindrical cartridge filter
* Input power supply : Single-phase AC 230 V (50/60 Hz)
* Power consumption : 200 W (50 Hz) / 280 W (60 Hz)
* Current consumption : 1.2 A (50 Hz) / 1.4 A (60 Hz)
* Dust collection airflow : 3.3 m3/min (50 Hz) / 4.0 m3/min (60 Hz)
* Static pressure : 0.88 kPa (50 Hz) / 1.23 kPa (60 Hz)
* Table surface controlled air speed : 0.4 m/sec (50 Hz) / 0.5 m/sec (60 Hz)
* Dust collection volume : 1.2 L
* Dust collector output : 200 W
* Airflow : 355L/min (0.7 MPa)
* Air supply hose diameter : 6 mm × 4 mm
* Operating temperature and humidity : 0°C to 40°C, 20% to 80% RH (non-condensing, non-freezing)
* Noise : 62 dB (A) (50 Hz) / 65 dB (A) (60 Hz)
* Accessories : Plastic adjusting screwdriver for sensor,hazardous use prohibited display sheet